2-31
Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide
OL-29284-01, Release 6.x
Chapter 2 Configuring Interfaces
Configuring Interfaces
Switch# show port internal info interface fc8/3
fc8/3 is down (Error disabled - port down due to trustsec violation)
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 21:c3:00:0d:ec:10:57:80
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port vsan is 1
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
11274 frames input, 1050732 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
11242 frames output, 971900 bytes
0 discards, 0 errors
11 input OLS, 34 LRR, 10 NOS, 0 loop inits
72 output OLS, 37 LRR, 2 NOS, 0 loop inits
Interface last changed at Sun Nov 27 07:34:05 1988
admin port-down trustsec-violation(3) num_times 0, duration = 0
state reason (Error disabled - port down due to trustsec violation)
Port guard trustsec violation is Enabled
errdisabled on trustsec violation TRUE, oper cnt = 1
port guard first trustsec violation Sun Nov 27 07:34:05 1988
Troubleshooting Tips
Link down is the superset of all other causes. A port is brought to down state if the total number of
other causes equals to the number of allowed link-down failures.
Even if the link does not flap due to failure of the link, and port guard is not enabled, the port goes
into a down state if too many invalid FLOGI requests are received from the same host. Use the shut
and the no shut commands consecutively to bring up the link.
Configuring Port Monitor
This section includes the following topics:
Enabling Port Monitor, page 2-31
Configuring a Port Monitor Policy, page 2-32
Activating a Port Monitor Policy, page 2-34
Enabling Port Monitor
Detailed Steps
To enable port monitor, follow these steps:
Command Purpose
Step 1
switch# config t
Enters configuration mode.
Step 2
switch(config)# port-monitor enable
Enables (default) port monitoring.
switch(config)# no port-monitor enable
Disables port monitoring.