Cisco Systems SF300-24P Manuel d'utilisateur Page 83

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 483
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 82
Administration: General Information
Monitoring Fan Status
Cisco Small Business 300 Series Managed Switch Administration Guide 66
5
To view the device health parameters, click Status and Statistics > Health.
The Health page displays the following fields:
Fan Status—Fan status. The following values are possible:
- OK—Fan is operating normally.
- Fail—Fan is not operating correctly.
- N/A—Fan ID is not applicable for the specific model.
Fan Direction—(On relevant devices) The direction that the fans are
working in (for example: Front to Back).
At least one temperature
sensor exceeds the Critical
threshold
The following are generated:
SYSLOG message
SNMP trap
The following actions are performed:
System LED is set to solid amber (if hardware
supports this).
Disable Ports — When the Critical
temperature has been exceeded for two
minutes, all ports will be shut down.
(On devices that support PoE) Disable the
PoE circuitry so that less power is consumed
and less heat is emitted.
Cool down period after the
Critical threshold was
exceeded (all sensors are
lower than the Warning
threshold - 2 °C).
After all the sensors cool down to Warning
Threshold minus 2 degree C, the PHY will be re-
enabled, and all ports brought back up.
If FAN status is OK, the ports are enabled.
(On devices that support PoE) the PoE circuitry is
enabled.
Event Action
Vue de la page 82